Heaters/Coolers store gas within themselves, causing inaccuracies with connected pipe systems
Created by: D3athrow-Issues
(WEB REPORT BY: bobda REMOTE: 172.93.109.202:7777)
Revision (Should be above if you're viewing this from ingame!) 1686bb32
General description of the issue Heaters/Freezers appear to store air within themselves as they do their job, this leads to canisters they are connected to not updating with the correct temperature.
What you expected to happen If the freezer indicates a gas is say 80K, the canister it is cooling is 80K
What actually happened The canister desyncs with the freezer and has to be unwrenched/wrenched to update, it ends up being 82K~
Steps to reproduce if possible
- Have a single freezer, connector and canister of whatever and set it up.
- Set the freezer to cool to whatever.
- Once it gets there, unwrench and wrench the canister and behold the freezer status display as the gases update.