Metaclobber Fixes and Changes
Created by: IratePirate
-extensive changes to atmos and engineering -paramedics officer added -some vents removed from maint so MoMMIs don't want to slice their wrists when ventcrawling -lots (and I mean lots) of other smaller changes
Feel free to sort through this list if you really want. It's very fragmented.
folder on mechanics desk merges into the thing on top of it remove light switch NW of PA add supermatter shard to secure storage delete glass walkway around atmos inner wall fix engineering wires in PA area going under the tiles remove firelocks from singularity windows and delete reinforced full windows needs an isolator in virology move air alarm in west medbay entrance changed motion sensor camera in AI upload entrance to normal camera fix area zoning on maint doors for rad storms add rechargers to mining make singo doors EMP proof 4way manifold is under the tiles in north atmos add EFPTOS scanners make it so engineering and supermatter have simulation disabled add air vents and scrubbers to PA chamber and supermatter foyer injectors in atmos need to be set to on remove maint next to captains? expand captains fix CE office APC having the wrong wire add an airlock to space near SME delete extra windoor near minisat space entrance widen AME room entrance by deleting Sec office? gas tank, freezer, connect it with h/e pipes around the room fix scrubber line south of AME room, it goes under a shuttle tile add centrifuge to virology delete maintenance vents make the names of vents and cameras more consistent add mommi spawner on derelict and gas miners with sci-kit fix maintenance area zoning fix captains desk rwalls west of tech storage add lights north and south of collectors add light to south of the safe in CE office remove light above computers in CE office make CE privacy shutters actually block light when down have floodlight in atmos turned on by default check area by the heaters in atmos delete boxes in atmos monitoring air alarm in engi foyer move it left replace floor under transit tube scrubber line in teleporter delete extra light in minisat east wing delete fire extinguisher in minisat access put light in sleeper room on opposite wall and add tiny light below leftscanner delete transit tube part south of shuttle computer at research stationdock air vent in engineering corridor should be in alignment with the scrubber light up holodeck? fix paper in holodeck check access on shooting range mvoe fire extinguisher on sec corridor rotate ai upload computers/windoor fix test chamber blast doors in telescience fix layout in theatre backroom, apc raise pepper shaker and pie move air alarm in bar to other side move command hallway maintenance back down a tile and add one tilewindows east air alarm in command hallway is too far up fix fire extinguisher in EVA remove EVA and gateway buttons from bridge fix glass pane on the bridge fix light switch in east bridge being visible from outside fix bridge fire axe inside the wall switch around captains laser and display case replace large light in captains bog with a small light and raise mirror fix tiles in kitchen back room remove double light switches, hydroponics backroom remove a heater from atmos only need one add hazard strips to smes room add lights to singo containment and hazard warnings